Abstract

The experimental time required to measure water vapour permeability of barrier film using the cup method is extremely long. In this study, a new technique is proposed, based on light transmission. This fast and accurate method was first validated using model films constituted of aluminized PET (polyethylene terephthalate) with aluminium layers of different thicknesses (<100 nm). It was possible to show that the ‘illuminating’ method could advantageously be employed to control the film’s barrier properties during their fabrication. In a second step, the method was tentatively used to measure the changes in barrier properties over time, when the samples are submitted to severe hydrothermal ageing (70 °C, 90% relative humidity [RH]). It was concluded that the complex degradation mechanism prevents accurate measurement while ageing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.