Abstract
We used dibasic acid esters as the absorbent for a volatile organic compounds (VOC) recovery and reuse system geared mainly toward VOCs from painting and presswork. The system consists of three elements: absorption using dibasic acid esters, separation by vacuum spray flash method, and recovery by condensation. The concentration of both ethyl acetate (EtAc) and isopropyl alcohol (IPA) decreased around 90% at room temperature. Vacuum spray flash was found as a useful process for cost-effective and energy-effective VOC removal system. The difference in the dissolubility parameters (Hansen constant) between dibasic acid esters and VOCs and the boiling point of VOCs was the main contributor to the separation behavior.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.