Abstract

Distinguishing between sealants and providing laboratory prognostic tools is essential for qualifying new sealants. Current test methods do not provide adequate discrimination between sealants. A laboratory test based on electrochemical impedance spectroscopy (EIS) supplemented by adhesion strength measurements and examination of sealed, bimetallic surfaces has been developed to give an early indication of sealant performance. Specimens using one of two different nonconductive sealants underwent hot-salt-water exposure followed by EIS measurements, pull strength measurements, and visual inspection. Defective sealant bonded specimens were readily detected by EIS. Absorption of moisture by the sealants was also detected and quantified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.