Abstract

An electrochemical immunosensor for direct detection of the 15.5-kDa protein interferon-gamma (IFN-gamma) at attomolar level has been developed. Self-assembled monolayers (SAMs) of cysteine or acetylcysteine are formed on electropolished polycrystalline Au electrodes. IFN-gamma adsorbs physically to each of these SAMs. With injections of 100 mM KCl, IFN-gamma can be removed in the flow without damaging the acetylcysteine SAM. However, the cysteine SAM is affected by these KCl injections. In an on-line procedure in the flow, a specific antibody (MD-2) against IFN-gamma is covalently attached following carbodiimide/succinimide activation of the SAM. The activation of the carboxylic groups, attachment of MD-2, and deactivation of the remaining succinimide groups with ethanolamine are monitored impedimetrically at a frequency of 113 Hz, a potential of +0.2 V versus SCE, and an ac modulation amplitude of 10 mV. Plots of the real (Z') and imaginary (Z") component of the impedance versus time provide the information to control these processes. In the thermostated setup (23.0 degrees C), samples of unlabeled IFN-gamma (in phosphate buffer pH 7.4) are injected and the binding with immobilized MD-2 is monitored with ac impedance or potential-step methods. While the chronoamperometric results are rather poor, the ac impedance approach provides unsurpassed detection limits, as low as 0.02 fg mL-1 (approximately 1 aM) IFN-gamma. From a calibration curve (i.e. Z" versus the amount injected), recorded by multiple 50-microL injections of 2 pg mL(-1) of IFN-gamma, a dynamic range of 0-12 pg mL(-1) could be derived. However, when nonspecific adsorption is taken into account, which has been found to be largely reduced through injections of 100 mM KCl, a much smaller dynamic range of 0-0.14 fg mL(-1) remains. The immunosensor can be regenerated by using a sequence of potential pulses in the flow by which the SAM with attached MD-2 and bound IFN-gamma is completely removed. When the developed procedures described above are repeated, the response of the immunosensor is reproducible within 10%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.