Abstract

An eddy current inspection system that incorporates a C-core probe and a direct current magnetizer for HP-grade ethylene pyrolysis tubes was developed to estimate the degree of carburization of the tubes. Through the development process, the characteristics of the B–H curves and the electric conductivities of service-aged tubes were clarified, and a method of counteracting the external magnetism of the tube, which disturbs the accurate detection of the degree of tube carburization, by installing a direct current magnetizer was validated. The influence of tube external magnetism in the oxide/nitride layer was properly canceled by installing a magnetizer with a magnetizing current of 0.5 A on the external surface of the tube. In addition, a calibration curve correlating the carburization depth from the external surface of the tube with the normalized inductance was obtained by finite element analysis simulation. The calibration curve revealed that the degree of carburization could be quantitatively evaluated from the detected normalized inductance of service-aged tubes using the developed inspection system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.