Abstract

The development of an analytical method for the determination of four selected pyrethroid insecticides at residue level in beef meat is presented. Acetone and petroleum ether at 40-60 degrees C were chosen as extraction solvents. A two-step clean-up was performed using an Extrelut NT3-C(18) system followed by a Florisil column, with disposable, ready-to-use cartridges. Instrumental analysis was carried out on a gas chromatograph equipped with an electron capture detector (GC-ECD), using matrix-matched and internal standard calibration techniques. Confirmatory analysis by GC-MS was performed. Recoveries at the EU Maximum Residue Limit (MRL), 0.5 x MRL and 1.5 x MRL levels and the repeatabilities were widely satisfactory. The main advantage of the method was the reduction of analysis time as compared with previously published works. The applicability of the method to different matrices and pesticide classes will be investigated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.