Abstract

The objective of this study was to develop a rapid and simplified, reliable high-performance liquid chromatography (HPLC) method for quantification of cefpirome (CAS 98753-19-6) in plasma. After precipitation of the plasma containing the internal standard, hydrochlorothiazide, with 5% trichloroacetic acid (TCA), the analysis of the cefpirome level in the plasma samples was carried out using a reverse-phase C18 column with the ultraviolet detector set at a wavelength of 258 nm. The chromatographic separation was accomplished with an isocratic mobile phase consisting of acetonitrile-acetate buffer pH 5. The proposed method was specific and sensitive with a lower limit of quantitation (LLOQ) of 0.5 microg/ml. This HPLC method was validated by examining the precision and accuracy for inter- and intra-day analysis in the concentration range 0.5-64.0 microg/ml. The relative standard deviation in the inter- and intra-day validation was less than 3%. Analytical recovery was more than 84%, and cefpirome was found to be stable in human plasma during both the storage and assay procedures. A satisfactory pharmacokinetic study of cefpirome was carried out in rabbits using the devised procedure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call