Abstract

To prepare the radioisotope Ac-225 using the liquid target of the Ra-226 chloride, and to evaluate the durability of the liquid target for this purpose. We will use Barium, a family like Radium. The Ba target was prepared by dissolving BaCl2 in DI water. An amount of 20 g/100 mL was prepared considering the solubility of BaCl2 (35.8 g/100 mL, 20°C) and the amount of 2 mL was loaded on the liquid target. The beam test was carried out using CYCLON 30 Cyclotron (Korea Institute of Radiological & Medical Sciences, IBA, 2001). The target was a large-volume liquid target of IBA and irradiated with energy of 15 - 30 MeV. To optimize irradiation energy and current conditions. To confirm the nuclear transformation, the irradiated target was analyzed using the HPGe detector for γ-spectrum.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.