Abstract

ABSTRACTAn alternative zonal fire main system concept is presented and compared to a typical combatant fire main system to determine the potential for affordability gains while maintaining capability. A combatant (DDG‐51) fire main system was modeled in a computer aided design (CAD) system along with the alternative zonal architecture system. The zonal architecture utilizes nine vertical zones as opposed to the conventional vertical offset loop system. Analysis indicates a 9% weight and 20% cost reduction can be achieved with a zonal architecture system. The system is being analyzed to determine if its performance is equivalent to conventional systems and may continue to evolve as additional studies are performed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.