Abstract

ABSTRACT The active rotation method is an innovative, transportable, active neutron method suitable for on-site detection of concealed nuclear material. Its assay system consists mainly of a neutron detector and a rotation device for rotating a neutron source such as californium-252. Although we previously demonstrated a low-cost rotation device, the neutron detector bank comprising helium-3 proportional counters was extremely expensive and had low detection efficiency, leaving the challenges of reducing cost and measurement time. In the present study, we developed a water Cherenkov neutron detector as a novel neutron detector for the active rotation method and demonstrated its suitability and effectiveness for nuclear material detection, meeting the cost, efficiency, and transportability criteria for nuclear security.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call