Abstract

A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spine and lower abdomen and the locations of several organs such as kidneys, liver and stomach between the two phantoms. Specific absorbed fractions (SAFs) for 24 target and 11 sources organs were calculated for monoenergetic photon ranging from 0.01 to 4 MeV. It was found that the SAFs for the kidneys as source organ and the lower large intestine wall as target organ in JM2 were significantly higher than those in JM for all photon energies. The differences of the SAFs between the two phantoms were attributed to the differences in the organ distance and organ geometry depending on the posture.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.