Abstract

A simple, accurate, reproducible and specific stability-indicating RP-HPLC method was developed for estimation of ethionamide in tablets. Ethionamide was exposed to acid, alkali and neutral hydrolysis at elevated temperatures, to thermolytic degradation, peroxide-mediated oxidation at room temperature in dark and to photolytic degradation. The drug was found stable to thermolytic and photolytic conditions and to neutral hydrolysis. However, substantial degradation was obtained in acid and alkali hydrolysis and complete degradation in peroxide-medicated oxidation. Similar degradation behavior was observed when ethionamide tablets were exposed to the mentioned forced degradation conditions. The method showed adequate resolution of drug from its potential degradation products on C18 (250 × 4.6 mm, 5µ) column using mobile phase of methanol: water (50: 50 % V/V) at 1 mL/min. The drug and its potential degradation products were detected at 290 nm. The method was validated as per the ICH Q2(R1) guidelines. The enrichment of the alkali degradation product was performed and isolated by preparative TLC and further confirmed by NMR and IR spectroscopy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.