Abstract
A simple and sensitive HPLC method was developed and validated for the determination of four frequently prescribed 1,4-benzodiazepines: alprazolam (ALP), bromazepam (BRZ), diazepam (DZP), and flunitrazepam (FNZ). Separation was achieved on an Inertsil C8 analytical (250 mm x 4 mm, 5 microm) column, after selective extraction of benzodiazepine drugs from biological matrices by means of SPE. Isocratic elution was performed with a mobile phase consisting of CH3COONH4, 0.05 M CH3OH, and CH3CN (33:57:10 by volume). Quantification was performed at 240 nm with mefenamic acid (6 ng/microL) as the internal standard. DSC-18 Supelco cartridges provided high absolute recoveries (81-115%). The developed method was fully validated in terms of selectivity, linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 8) and between-day precision (n = 8) revealed RSD <12%. Recoveries from biological samples ranged from 81.2 to 115%. The detection limit of the method was calculated as 3.3-10.2 ng in blood plasma and 2.6-12.6 ng in urine for 20 microL injection volume. The method was applied to spiked biological matrices. Moreover, the method was applied to real samples of urine after an oral administration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.