Abstract

The accumulation and behavior of impurities is one of the most important subjects in the development of magnetically confined fusion reactors because impurities can potentially cause cooling and worsen the confinement of the hot core plasma. Tracer-encapsulated solid pellets (TESPELs) have demonstrated some results for impurity injection for fusion-reactor plasma studies [N. Tamura et al., J. Phys. Conf. Ser. 823, 012003 (2017)]. However, the TESPEL technique has several shortcomings, for example, the penetration depth and the amounts of tracer impurities. In the present study, we have developed a tracer-containing, compact-toroid (TCCT) injection system that utilizes a magnetized coaxial plasma gun (MCPG). The discharge current through the MCPG sputters and ionizes the electrode material, and the Lorenz self-force accelerates it as a plasmoid. The MCPG easily accelerates a magnetized plasmoid to speeds greater than the ion thermal velocity of several tens of kilometers per second. The accelerated and ejected plasmoid that contains the tracer ions is itself a warm, ionized plasma. Therefore, a TCCT can potentially be injected into the core region of a target plasma with less adverse effect.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call