Abstract

A single loop electrochemical potentiokinetic reactivation test method has been developed for alloy 600 that produces good passivation on all the surfaces, good etching during the reactivation scan and no appreciable pitting. It is able to quantify and discriminate between samples with a wide range of degree of sensitization. The Pa value correlates well with the minimum level of chromium in the depletion regions at the grain boundaries. It has been shown that the width of the attacked regions is much larger than the width of chromium depletion regions and it does not show any direct correlation with either depth or width or with a volume parameter of chromium depletion regions. It has been shown that the chromium carbides are not attacked during the test and that the intragranular regions attacked during the test are the sites of chromium carbides in the grain matrix. A modified Pa parameter is shown to be sensitive down to 7.5 wt% chromium in the depletion regions and indicates that the intragranular carbides have shallower depletion profiles than those at grain boundaries. Comparison of the results of the single loop and the double loop tests showed a good correlation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.