Abstract

Obestatin is a gastrointestinal system peptide. The quantification of this peptide is conventionally performed using immunological techniques. In this study, a selective and sensitive HPLC method coupled with fluorescence detection for the quantitation of obestatin in human plasma was developed and validated. The separation was obtained on a C18 (4.6 × 100 mm, 3.5-μm particles) column using a mobile phase composed of acetonitrile and water, both including 0.1% trifluoroacetic acid. The developed method was found to be linear in the concentration range of 20 to 1000 ng/mL, with a coefficient of determination of 0.9982. The precision results were less than 10%, and the accuracy results were between 92% and 107%. The detection and quantification limit values were obtained as 2.8 and 9.4ng/mL, respectively. Analyte solutions were found stable for 24 h at room temperature, three freeze-thaw cycles, and 2weeks at -20°C. The developed method was successfully used for the quantification of obestatin in human plasma samples. In conclusion, the developed method is sensitive and specific for measuring the plasma concentrations of obestatin.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call