Abstract

The accuracy and the efficacy of radiological diagnosis depend, to a large extent, on the conditions under which radiographs and images are viewed. This mainly involves the luminance of the display devices and the ambient room illumination. We report a perceptual study to investigate the relationship between detectability and monitor luminance as well as ambient illuminance. A statistical test pattern was used in this study, and the test pattern was developed using Microsoft® Visual Basic 6. The test pattern contained a set of randomised contrast detail objects, that is, disks of different diameters (0.7, 1.0, 1.4, and 2.0 mm) and contrasts against a black background (2.7, 3.9, 5.5, and 7.8%), simulating lesions in digital images. The receiver operating characteristic (ROC) analysis was used in this study. The results indicated that a set of optimal viewing conditions exists and that it has a significant effect on detectability performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.