Abstract

In situ abdominal normothermic regional perfusion (A-NRP) has been used for liver transplantation (LT) with donation after circulatory death (DCD) liver grafts in Europe with excellent results; however, adoption of A-NRP in the United States has been lacking. The current report describes the implementation and results of a portable, self-reliant A-NRP program in the United States. Isolated abdominal in situ perfusion with an extracorporeal circuit was achieved through cannulation in the abdomen or femoral vessels and inflation of a supraceliac aortic balloon and cross-clamp. The Quantum Transport System by Spectrum was used. The decision to use livers for LT was made through an assessment of perfusate lactate (q15min). From May to November 2022, 14 A-NRP donation after circulatory death procurements were performed by our abdominal transplant team (N = 11 LT, N = 20 kidney transplants, and 1 kidney-pancreas transplant). The median A-NRP run time was 68 minutes. None of the LT recipients had post-reperfusion syndrome, nor were there any cases of primary nonfunction. All livers were functioning well at the time of maximal follow-up with zero cases of ischemic cholangiopathy. The current report describes the feasibility of a portable A-NRP program that can be used in the United States. Excellent short-term post-transplant results were achieved with both livers and kidneys procured from A-NRP.