Abstract

This solar conversion system incorporates a suction fan powered by a solar PV module. Located at the outlet of the chamber is the d.c suction fan utilised to achieve forced air circulation without the use of external power supply like grid electricity, fossil fuel and battery. Simple thermal energy balance equations and heat transfer equations were employed in the design of the system. The operational efficiency of the collector is 83.2% and mass flow rate 1.58kg/min, the maximum temperature achieved in the chamber was 58oC. The system was used to dry vegetable, hydrophylum. The capital cost is less than $150.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.