Abstract

Abstract A new subassembly type passive reactor shutdown device is proposed to expand the diversity and robustness of core disruptive accident prevention measures for sodium-cooled fast reactors (SFRs). The device contains pins with a fuel material that is in a solid state during normal operation but melts and fluidizes during an unprotected loss of flow (ULOF) or unprotected transient overpower (UTOP) accident. By rapidly transferring the liquefied device fuel into the lower plenum region of the pins via gravitation alone, the device passively provides high negative reactivity to the core. This study evaluated the nuclear and thermal properties of the device subassembly with metallic fuel to determine the device specifications for proper device operation during ULOF and UTOP accidents. The results of the transient analysis of the ULOF initiating phase in a 750-MWel-class mixed-oxide-fueled SFR core confirmed that a conventional homogeneous core maintains stable cooling of the core before coolant boiling in the driver fuel subassemblies. In contrast, the negative reactivity required to terminate the event by device operation was slightly higher in the low sodium void reactivity core than in the conventional homogeneous core.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call