Abstract

Owing to high tensile strength, corrosion resistance and low weight, prestressed carbon fibre-reinforced-polymer (CFRP) plates have rapidly increasing applications in bridges, tall buildings, tunnels, high-speed trains, automotive, aviation, satellite and shipbuilding industries. This article illustrates the design of an innovative prestressing anchor for the popular 50mm wide and 1.2mm thick CFRP plates. This novel mechanical anchor can grip and prestress the CFRP plate to its full tensile capacity of 168kN without any premature failure. This article focuses on the experimental investigation of prototypes of the new anchor, the experimental setup and the experimental results of twenty-two static tension tests. The new anchor was optimized through a sequential testing program for different design parameters. The average failure load of the new anchor was 187±6kN. The failure mode of the anchor was the tensile rupture of the CFRP plate at its free length outside of the anchor. This innovative post-tensioning anchor will be used to rehabilitate and retrofit reinforced concrete structures by flexural strengthening of the structures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.