Abstract
In this paper, a new method of baseline correction on strong motion acceleration records is presented and the fundamental concept for baseline corrections on the earthquake strong motions is described. Considering the filtering effect, the earthquakes ground motion displacements of 1995 JMA KOBE, 1999 Kocaeli YPT and 1999 Chi-Chi TCU068 are discussed. Also, the linear sloshing responses of large liquid tanks subjected to these motions were discussed. Since liquid storage tanks show the low frequency (long period) sloshing characteristics and the strong motion characteristics of 1999 Kocaeli and Chi-Chi earthquakes are also low frequencies and large permanent displacements, the sloshing responses in large liquid tanks, especially in long natural periods, were significantly affected by the low frequency motions (large permanent displacements) of these devastating earthquakes. It is very important to use suitable ground motion characterized low frequency content for earthquake resistant design of liquid storage tanks. The baseline correction method presented in the paper may be adequately used to correct strong motion records for large liquid storage design.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.