Abstract

BackgroundS. pyogenes, is a primary pathogen that leads to pharyngitis and can also trigger severe conditions like necrotizing fasciitis and streptococcal toxic shock syndrome (STSS), often resulting in high mortality rates. Therefore, prompt identification and appropriate treatment of S. pyogenes infections are crucial in preventing the worsening of symptoms and alleviating the disease's impact. ResultsIn this study, a newly developed technique called multiple cross displacement amplification (MCDA) was employed to detect S. pyogenes,specifically targeting the speB gene, at a temperature of 63°C within 30 min. Then, an easily portable and user-friendly nanoparticles-based lateral flow biosensor (LFB) assay was introduced for the rapid analysis of MCDA products in just 2 min. The results indicated that the LFB offers greater objectivity compared to Malachite Green and is simpler than electrophoresis. The MCDA-LFB assay boasts a low detection limit of 200 fg and exhibits no cross-reaction with non-S. pyogenes strains. Among 230 clinical swab throat samples, the MCDA-LFB method identified 27 specimens as positive, demonstrating higher sensitivity compared to 23 samples detected positive by qPCR assay and 18 samples by culture. The only equipment needed for this assay is a portable dry block heater. Moreover, each MCDA-LFB test is cost-effective, priced at approximately $US 5.5.ConclusionThe MCDA-LFB assay emerges as a straightforward, specific, sensitive, portable, and user-friendly method for the rapid diagnosis of S. pyogenes in clinical samples.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call