Abstract

Abstract This paper presents the development and verification of a heat exchanger model for evaluating thermal performance of an evaporator for a CO2 mobile air-conditioning system. The model has been developed, based on the finite volume method, with emphasis on the air-side heat and mass transfer process. The governing equations are derived from mass and energy balances using newly developed air-side heat transfer and friction loss correlations for micro-channel heat exchangers under dry and wet conditions. The calculated air-side heat transfer and pressure drop data are in good agreement with measured data. However, the refrigerant-side pressure drop estimation for micro-channel tubes usually underestimates the measured value. The simulation results and importance of selecting appropriate heat transfer and pressure drop correlations for the micro-channel heat exchanger are addressed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.