Abstract

A method for the determination of amizone and amixin in the same sample and in their mixture with antibiotics (ceftriaxone, tetracycline, ampicillin and levofloxacin) was developed using reversed-phase highperformance liquid chromatography equipped with a photodiode array detector. A SunFire C18 column, a mobile phase consisting of sodium perchlorate buffer (pH = 2.5) and acetonitrile (75:25), at a flow rate of 0.8 ml/min, was used. The analytes were identified at 205 and 265 nm. The specificity, linearity, precision parameters, LOD and LOQ were evaluated during the validation of the methodology, and the correlation coefficients of amizone and amixin were 0.9992 and 0.9998, respectively. This method can also be used for the determination of amizone and amixin and their presence in a mixture with antibiotics in the environment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.