Abstract

Development work was completed on a ROXNOX oxidation to harden the gate oxide against hot carriers. Although device lifetime criteria were met and exceeded, there were serious manufacturing problems which remained. These problems included nonuniform oxide, high particle counts and excessive equipment failures due to the high temperature required for the ROXNOX oxidation process. A series of equipment and process solutions resulted in a factor of 2 film uniformity improvement, a factor of 2 reduction in average particle counts and a reduction of the occurrence and magnitude of particle spikes as well as improvement in equipment availability by 20%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.