Abstract

A prototype adiabatic demagnetization refrigerator (ADR) operating between 2 K and 10 K has been built and tested. The refrigerant for the ADR is Gadolinium Gallium Garnet (GGG). In the design thick slices of single-crystal GGG are sandwiched together with strips of high-purity copper. The copper strips are used to transfer heat between the GGG and the 2 K and the 10 K heat switches. The heat switches employed in the ADR have no moving parts. The 10 K heat switch is a helium gas-gap heat switch; while, the 2 K heat switch is a He II-gap heat switch. Preliminary tests indicate that the prototype ADR can provide 27 mW of cooling at 2 K for 165 s; where, the cycle period is 12.6 minutes. The efficiency of the ADR relative to Carnot is 25%. Methods for improving the efficiency of the system are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.