Abstract
Loop-mediated isothermal amplification (LAMP) is a novel, rapid nucleic acid amplification method with high specificity and sensitivity under isothermal conditions. In this study a LAMP assay for diagnosing Pneumocystis pneumonia (PCP) was developed. Oligonucleotide primers specific for Pneumocystis species were designed corresponding to 18S rRNA gene sequences. The assay, performed for 30 min at 61 degrees C, was capable of detecting 50 copies per tube (2 x 10(3) copies ml(-1)) in 30 min and did not show cross-reactivity to other species of fungi, including the genera Candida, Aspergillus and Cryptococcus. A total of 21 of 24 clinical specimens (sputum and bronchoalveolar lavage fluid) from patients with suspected PCP tested positive using the LAMP assay by real-time fluorescence detection. The results of the LAMP reaction were also observed by real-time turbidity detection and end-point visual turbidity or fluorescence detection. With real-time fluorescence detection, melting curves of the products were effective at distinguishing specific amplification from non-specific amplification or self-amplification. Visual detection was also possible as a rapid and easy assay using only a heat block and a black light.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.