High performance transfer lines are key components for design and construction of cryogenic systems for superconducting magnets and cavities. We have developed two types of high performance transfer lines; main transfer lines with liquid helium flow and cold gas return dual path and sub-transfer line with single path, all helium lines in these are guarded by 80K liquid nitrogen cooled thermal shields. We have adopted the aluminum molding made by extrusion for the 80K thermal shields. The structure of the transfer lines was designed to be easy to assemble. The performance of these transfer lines were tested. The heat loss of the main transfer lines at straight section are 0.04W/m and 0.06W/m for supply and return line, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.