Abstract

For the European spallation source, a volume source based on the high efficiency source is being developed. The source will be optimized to produce high current densities in pulsed operation. A pulse generator delivering 1–1.5 ms pulses was installed. Furthermore, cesium was supplied to the plasma generator from an external oven. The cesium injection was optimized for a low e/H− ratio and a high current. We obtained a current density of 70 mA/cm2. This way, with an aperture radius of 4.25 mm, an H− current of 40 mA was extracted at an extraction voltage of 22 kV. After a description of the source and the experimental setup, measurements of the beam current density and the e/H− ratio will be presented in this article.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.