Abstract

We constructed a hadron blind detector (HBD) using a finely segmented pad readout. The finely segmented pad readout enabled us to adopt an advanced particle identification method which applies a threshold to the number of pad hits in addition to the total amount of collected charge. The responses of the detector to electrons and pions were evaluated using a negatively charged secondary beam at 1.0GeV/c containing 20% electrons at the J-PARC K1.1BR beam line. We observed 7.3 photoelectrons per incident electron. Using the advanced particle identification method, an electron detection efficiency of 83% was achieved with a pion rejection factor of 120. The method improved the pion rejection by approximately a factor of five, compared to the one which just applies a threshold to the amount of collected charge. The newly introduced finely segmented pad readout was found to be effective in rejecting pions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call