Abstract

In this work, a finite element model was developed to study mechanoelectrochemical effect of pipeline corrosion through a multiphysics field coupling technique. The modeling results, i.e., corrosion potential and corrosion current density, are well consistent with experimental measurements on pipeline steel in a near-neutral pH solution. It is demonstrated that, while a tensile strain enhances stress uniformly through pipe wall, an increasing depth of corrosion defect results in a concentrated stress at the defect center only. When the corrosion defect is under an elastic deformation, there is no apparent effect of mechanical–electrochemical interaction on corrosion. However, when the applied tensile strain or the geometry of corrosion defect is sufficient to cause a plastic deformation at the defect, the local corrosion activity is increased remarkably. Corrosion at the defect is composed of a series of local galvanic cells, where the region with a higher stress, such as the defect bottom, serves as anode, and that under lower stress, such as the defect sides, as cathode. The locally accelerated corrosion at the defect center can be further enhanced as the corrosion defect deepens.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.