Abstract

Only a few works on fatigue behavior of thin films under tension–tension loading can be found because of some limitations of a testing system. In this study, a fatigue testing system capable of performing load controlled tension–tension fatigue tests even for ductile thin films was developed by using an electrodynamic actuator. With the system, fatigue testing can be performed over a wide range of loading frequency. Besides, a capacitive displacement gauge was developed to measure the monotonic and cyclic deformation of thin films with high resolution during fatigue testing. As the displacement gauge is stable and its response is so fast, the displacement can be measured instantaneously and continuously during fatigue testing of high frequency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.