Abstract

A dummy load dissipates the radiofrequency power and is required for the electron cyclotron heating system to test and adjust a gyrotron or a transmission line in ITER and JT60SA. The dummy load is comprised of a water-cooled vacuum chamber and a reflector. The vacuum chamber has intensive cooling and the inside surface has a ceramic coating layer. It is important that the dummy load has reliable durability and long lifetime. Linear movement is used as a main mechanism for the reflector to mitigate the heat deposition concentration instead of rotating reflector. The vacuum boundary for the linear movement is simply made with bellows and the bellows is accessible from the outside. The distribution of the ceramic coating thickness is carefully optimized considering the heat deposition rate. Another critical issue is to minimize the back reflection of the RF power from the dummy load. However, it is desired to design the dummy load without the pre-dummy-load. A prototypical dummy load will be manufactured and tested, following the design phase.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.