Abstract

Myriad neuropsychiatric disorders are due to dopamine dysfunction. However, understanding these disorders is limited by our ability to measure dopamine storage and release. Fluorescent false neurotransmitters (FFNs), small-molecule dyes that co-transit through the synaptic vesicle cycle, have allowed us to image dopamine in cell culture and acute brain slice, but in vivo microscopy is constrained by the biopenetrance of light. Here, we adapt FFNs into magnetic resonance false neurotransmitters (MFNs). The design principles guiding MFNs are (1) the molecule is a valid false neurotransmitter and (2) it has a 19F-substituent near a pH-sensing functional group, which (3) has pKa close to 6 so that the probe within vesicles is protonated. We demonstrate that MFN103 meets these criteria. While a magnetic resonance spectroscopy (MRS) signal was too low for measurement in vivo with the current technology, in principle, MFNs can quantify neurotransmitters within and without synaptic vesicles, which may underlie noninvasive in vivo analysis of dopamine neurotransmission.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.