Abstract
This paper introduces a new close-range photogrammetric bridge deflection measurement system that has high accuracy and efficiency, and can be conveniently used by engineers without help from professional surveyors. After a general description of a photogrammetric bridge deflection measurement system, four critical components of the system are addressed in detail: camera selection and settings; camera calibration; network control (reference system and scale); and camera placement. The system configuration is introduced and the system is verified through the laboratory and field tests.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.