Abstract
The paper discusses possible ways of increasing beam brightness in ion injectors. The argon/helium ion injector comprising a newly designed RF ion source and, a Wien filter has been designed for use in accelerator-based nanoprobe facilities. The phase set degradation due to aberrations in the injector ion-optic system was simulated with allowance for multipole and fringing fields. The RF ion sources with different permanent magnet systems were tested. Experiments were performed with argon and helium. A plasma density of up to 3×10 11 cm −3 and beam brightness of ∼100 A/(m 2 rad 2 eV) were obtained. The ion current density inside an extracting electrode in the source was 10 mA/cm 2 for an emission hole diameter of 0.6 mm. Measurements of the current value and emittance were performed with ion source testing equipment permitting measurements of the ion beam current, emittance, mass composition, and RF power input into the plasma.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.