Abstract

Microencapsulation is almost exclusively performed in batch processes. With today’s chemistry increasingly performed in flow reactors, this work aims to realise a continuous reactor setup for the encapsulation of an ester with a polyuria (PU) shell. The generation of an emulsion template is performed in a recirculation loop driven by a pump and equipped with static mixers, screen type and Kenics®. Calorimetric measurements are performed to characterise the energy dissipation rate inside the loop. The curing step is performed in a coiled tube reactor with two geometric configurations. Number based capsule size distributions are derived from micrograph analysis. Results indicate that the recycle pump is the main contributor to determine the capsule size distribution. A continuous setup is achieved for PU microcapsules containing hexyl acetate with a production rate of 198 g/h dry capsules, and a mean capsule diameter of 13.3 µm with a core content of 54 wt%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.