Abstract
In this paper, a compact torus (CT) injector system is designed for experimental advanced superconducting tokamak (EAST). The injector system consists of a coaxial electrode and four pulsed power systems and generates self-organized CT with high density and velocity. In addition, the performance of EAST-CTI is evaluated using a series of diagnostics systems. The experimental results show that the velocity, electron density, and number of particles of the CT are 56.0 km/s, 8.73 × 1020 m-3, and 2.4 × 1018, respectively. The detailed description and experimental results are presented in this paper.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.