Abstract

To achieve the application of a periodic permanent magnet in high power microwave, a compact coaxial cusped periodic permanent magnet (CPPM) focusing system is constructed. The system consists of permanent magnets with different magnetization directions and soft magnets. Taking the required magnetic field performance and the effect of demagnetization into account, NdFeB and FeCoV are selected as the permanent and soft magnet materials. After the system is constructed, the magnetic field is measured. The results show that the guiding magnetic field strength and period of the CPPM are about 0.29 T and 26 mm, respectively, and the magnetic field distribution of measurement shows good agreement with the simulation results. However, there are some differences between the measurement and simulation results, and the differences are compared and analyzed here.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.