Abstract

In nuclear power plants, instrument failures must be detected and compensated for before a significant decrease in plant performance occurs. The improved generalized likelihood ratio method to detect and identify a failure and a control algorithm in the event of an instrument failure is developed. The failure detection algorithm and the control algorithm are combined and applied to a pressurized water reactor pressurizer. Computer simulation tests show that on-line prompt failure detection and compensation through control action can be performed very successfully even when there is an instrument failure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.