Abstract

The outbreak of African swine fever (ASF) has caused significant economic losses to animal husbandry worldwide. Currently, there is no effective vaccine or treatment available to control the disease, and therefore, efficient disease control is dependent on early detection and diagnosis of ASF virus (ASFV). In this study, a chemiluminescent immunoassay (CLIA) was developed using the ASFV protein p54 as a serum diagnostic antigen and an anti-p54 monoclonal antibody. After optimizing the working parameters of the CLIA, the sensitivity of the established CLIA was 1:128, ASFV-specific serum antibody was identified, and there was no cross-reaction with other swine virus antibodies. After testing 49 clinical serum samples, the consistency rate between the CLIA and the World Organization for Animal Health (OIE) recommended commercial kit was 100 %. Thus, this CLIA had a high degree of specificity, sensitivity, and reliability, and could be used as a rapid detection method for epidemiological investigations of ASFV infection.