Abstract

A simple, rapid, and sensitive method has been developed for the analysis of sildenafil (S) and its N-Demethylated metabolite UK-103,320 (UK) using capillary gas chromatography with a flame ionisation detector. Optimal conditions were investigated, achieving analysis times shorter than 12 minutes. Aspects such as stability of the solutions, linearity, accuracy (<91%), precision, specificity, and limits of detection (0.02 mg/L and 0.12 mg/L for S and UK respectively) were tested in order to validate the method. A solid-phase extraction (SPE) prior to the analysis allows quantification of S in serum and urine, and UK in serum at clinically relevant concentrations. Furthermore the specificity has been assessed by means of mass spectrometry in SCAN mode.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.