Forced precipitation of struvite (MgNH4PO4 . 6H2O) can reduce dissolved reactive phosphorus (DRP) in swine manure slurries. Optimization of this process requires that the swine manure slurry pH be increased, that magnesium be added, and that sufficient reaction time be allowed for struvite precipitation. To gather data that could be used for a full-scale continuous-flow struvite precipitation reactor, a bench-scale (14-L) continuous flow reactor was designed, constructed, and tested. The bench-scale reactor used air sparging for both pH adjustment and mixing, used a peristaltic pump to continuously inject magnesium chloride (MgCl2 . 6H2O), and was operated at a 10-min hydraulic retention time. The bench-scale system provided a 95% reduction of DRP in swine manure slurry collected from a concrete storage tank with a permeable cover, and a 78% reduction of DRP in swine manure slurry collected from a shallow under floor pit collection system. A bench-scale up-flow clarifier was designed, constructed, and tested for continuous flow separation of the precipitated struvite in order to provide total phosphorus (TP) removal. The up-flow clarifier was unable to continuously settle struvite particles formed in the bench-scale reactor and provided no significant TP removal through the system. The implication of this work for full-scale systems is discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.