This paper presents the development of a 6-DOF (Degrees of Freedom) parallel robot for single-incision laparoscopic surgery (SILS). The concept of the robotic system is developed with respect to a medical protocol designed by the medical experts in the team targeting a SILS procedure in urology. The kinematic model of the robotic system was defined to determine the singularities that may occur during functioning. FEM analyses were performed to determine the components of the robotic structure that may compromise the rigidity of the robotic system, and these components were redesigned and integrated into the final design of the robot. To verify the kinematic model a series of numerical and graphical simulations were performed, while to test the functionality of the robotic system, a low-cost experimental model was developed. The accuracy of the experimental model was measured using an optical motion tracking system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.