Abstract

N2 O isotopomers are a useful tool to study soil N cycling processes. The reliability of such measurements requires a consistent set of international N2 O isotope reference materials to improve inter-laboratory and inter-instrument comparability and avoid reporting inaccurate results. All these are the more important given the role of N2 O in anthropogenic climate change and the pressing need to develop our understanding of soil N cycling and N2 O emission to mitigate such emissions. Cavity ring-down spectroscopy (CRDS) could potentially overcome resource requirements and technical challenges, making N2 O isotopomer measurements more feasible and less expensive than previous approaches (e.g., gas chromatography [GC] and isotope ratio mass spectrometry [IRMS]). A combined laser spectrometer and small sample isotope module (CRDS & SSIM) method enabled N2 O concentration, δ15 Nbulk , δ15 Nα , δ15 Nβ and site preference (SP) measurements of sample volumes <20 mL, such as static chamber samples. Sample dilution and isotopic mixing as well as N2 O concentration dependence were corrected numerically. A two-point calibration procedure normalised δ values to the international isotope-ratio scales. The CRDS & SSIM repeatability was determined using a reference gas (Ref Gas). CRDS & SSIM concentration measurements were compared with those obtained by GC, and the isotope ratio measurements from two different mass spectrometers were compared. The repeatability (mean ± 1σ; n = 10) of the CRDS & SSIM measurements of the Ref Gas was 710.64 ppb (± 8.64), 2.82‰ (± 0.91), 5.41‰ (± 2.00), 0.23‰ (± 0.22) and 5.18‰ (± 2.18) for N2 O concentration, δ15 Nbulk , δ15 Nα , δ15 Nβ and SP, respectively. The CRDS & SSIM concentration measurements were strongly correlated with GC (r = 0.99), and they were more precise than those obtained using GC except when the N2 O concentrations exceeded the specified operating range. Normalising CRDS & SSIM δ values to the international isotope-ratio scales using isotopic N2 O standards (AK1 and Mix1) produced accurate results when the samples were bracketed within the range of the δ values of the standards. The CRDS & SSIM δ15 Nbulk and SP precision was approximately one order of magnitude less than the typical IRMS precision. CRDS & SSIM is a promising approach that enables N2 O concentrations and isotope ratios to be measured by CRDS for samples <20 mL. The CRDS & SSIM repeatability makes this approach suitable for N2 O "isotopomer mapping" to distinguish dominant source pathways, such as nitrification and denitrification, and requires less extensive lab resources than the traditionally used GC/IRMS. Current study limitations highlighted potential improvements for future users of this approach to consider, such as automation and physical removal of interfering trace gases before sample analysis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call