Abstract
A simple, fast, sensitive method for the determination of preservatives (methyl parahydroxybenzoate, propyl parahydroxybenzoate) in the finished dosage form of sodium oxybutyrate syrup based on the simultaneous determination of preservatives using high performance liquid chromatography (HPLC) is proposed. The HPLC method was validated. The correlation coefficient of the linearity of the technique was 0.999 in the application range of 80–120 % of the normalized value. The calibration graph is linear in the region of 0.495–0.990 mg/ml of methyl 4-hydroxybenzoate and 0.165–0.330 mg/ml of propyl 4-hydroxybenzoate. It has been established that the analytical characteristics of the test procedure (selectivity, linearity, correctness, repeatability, reproducibility) satisfy the selected acceptance criteria.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of the National Academy of Sciences of Belarus, Chemical Series
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.