Abstract

A high performance reverse phase liquid chromatographic procedure is developed for simultaneous estimation of Metformin and Glibenclamide in combined tablet dosage form. The method was carried out on Agilent Hypersil ODS (4.6 x 250 mm) column with a mobile phase used consisting of Methanol: Water (0.1 % OPA) OPA= Ortho Phosphoric acid (80:20) and the pH of buffer was adjusted to 3 using 2M Orthophosphoric acid. The detection of the combined dosage form was carried out at 228 nm and a flow rate employed was 1 ml/min and column oven temperature at 300C. The retention times of Metformin andGlibenclamide were 3.4667 and 7.3500 minutes respectively. The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantification as per ICH norms. The proposed method can be used for the estimation of these combined drugs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.