A new analytical method using high-performance liquid chromatography coupled with photo diode array detection was developed and validated for the quantification of Diclofenac (DIC) from in vitro skin permeation samples. Analysis was performed using a Phenomenex C18 column (150 x 4.6mm, 5µm) with 10mM ammonium acetate: Acetonitrile (62:38% v/v) as the mobile phase in isocratic mode and eluents were monitored at 276nm. DIC was eluted at 3.1min and showed a good linearity in the concentration range of 0.2-3µg/mL with a correlation coefficient >0.999. The validation parameters, such as specificity, linearity, accuracy and limit of detection, limit of quantification, precision, robustness fulfilled the regulatory requirements. The developed HPLC method was successfully used for the analysis of DIC in samples obtained from transdermal diffusate samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.