Abstract
A simple, accurate, rapid and precise method was developed for the simultaneous estimation of Ibuprofen and Diphenhydramine in Pharmaceutical dosage form. Chromatogram was run through Inertsil ODS (250x4.6mm) 5µ. Mobile phase used was Acetonitrile and Phosphate buffer (45:55) at a flow rate of 1.0 ml/min and detection wavelength was found to be 260 nm. The retention time was found to be 2.32 min and 2.93 min for Ibuprofen and Diphenhydramine respectively. The accuracy and reliability of the method was assessed by evaluation of linearity, precision (intra-day and inter-day % RSD >2), accuracy (98-102%), specificity, LOD, LOQ values in accordance with ICH guidelines. The developed method is applicable for routine quality control analysis of selected combined dosage forms.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Research In Pharmaceutical Chemistry and Analysis
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.